Call Us: 1-613-619-0894

Electronic Power- and Energy Meters for Panel and Rail Mounting

Electronic Power- and Energy Meters for Panel and Rail Mounting

Typical Applications: Power- and energy metering, energy management and process control in buildings and plants

  • Multifunctional – All electrical values for power consumption
  • Per phase and totals of kW, kvar, V, A, PF (power factor)
  • Backlighted displays
  • High accuracies 0,2%
  • Alarm outputs, analog outputs
  • PC Interfaces RS422/485 or RS232
RM303D8/PowerRail 303 Model Description Application Inputs Meas. Values
RM303d8 kWh / kW Meter kWh metering in control panels, Energy Management, Rail Mounting 1 or 3 Phases, Volt & Amp kWh kWh, (kW for 1 minute)
Accuracy Interfaces Outputs Form Factor
Cl. 1 kWh No 1 Pulse Rail 6 units 106x90x58mm
PM380 Model Description Application Inputs Meas. Values
PM380-1 Panel Indicator Control panels – replacement for Volt, Amp, kW, PF & frequency indicators 3 Phases, Volt & Amp Per Phase V, I, kW & PF, 3 Phase kW, PF & Hz
Accuracy Interfaces Outputs Form Factor
±0.2% V & I ±0.4% Watt RS485 None Panel 96x96x80mm
Model Description Application Inputs Meas. Values
PM380-2 Indicator & Meter Control panels – replacement for Volt, Amp, kW, PF & frequency indicators plus kWh meter 3 Phases, Volt & Amp Per Phase V, I, kW & PF, kWh 3 Phase kW, PF & Hz.
Accuracy Interfaces Outputs Form Factor
Cl.1 kW, kWh RS485 1 Pulse Panel 96x96x80mm
Model Description Application Inputs Meas. Values
PM380-3 Indicator & Meter Control panels – replacement for Volt, Amp, kW, kvar, PF & frequency indicators, kW demand meter plus kWh & kvarh meters 3 Phases, Volt & Amp Per Phase V, I, kW, kvar & PF, 3 Phase kW, kvar, PF & Hz. kW MD kWh & kvarh
Accuracy Interfaces Outputs Form Factor
Cl.1 kW, kWh Cl. 2 kvarh RS485 2 Pulse Panel 96x96x80mm
Model Description Application Inputs Meas. Values
PM380-4 Indicator & Meter Control panels – replacement for Volt, Amp, kW, kVA, kvar, PF, frequency & neutral current indicators, kW demand meter plus kWh & kvarh meters 3 Phases, Volt & Amp Per Phase V, I, kW, kVA, kvar & PF, 3 Phase kW, kVA, kvar, PF & Hz. kW MD, kWh & kvarh, ceutral current, peak V & I
Accuracy Interfaces Outputs Form Factor
Cl.1 kW, kWh Cl. 2 kvarh RS485 2 Pulse Panel 96x96x80mm
MD = Maximum Demand
 TM396 -Leistungsmesser
Model Description Application Inputs Meas. Values
TM396 3 Phase Power Meter (Table-top Unit) U, I, kW, PF and Frequency, additional kWh und kvarh, Energy Management 3 Phasen, U & I P(ges)[kW], P(1,2,3)[kW], S(1,2,3)[kVA], S(ges)[kVA], Q(1,2,3)[kvar], Q(ges)[kvar], E(ges)[kWh], E(ges)[kvarh]ind, U(1,2,3)[V], U(LL)[V], I(1,2,3)[A], f[Hz], power on hours  resolution 0,1h, Rotating field indicator, Harmonics 1…15 von U und I, Part of harmonics THD U,I in%, contents PC software, Optional: Instead laboratoy connectors 32A CEE Connector
Accuracy Interfaces Outputs Form Factor
Cl.1 for kWh RS232, RS485-Modbus Protocol 2x Puls or 4-20mA Analogue Output Table-top Unit