New standard

Capacitance and frequency can be measured too

  • 4000 counts
  • Easy to read large LCD
  • Thermo plastic elstomer, high resistance against drop shock
  • Safety cap on current terminal
  • Auto power off (30min.)(cancelable)

CD 770

Digital Multimeters Standard type

New Standard

Capacitance and Frequency measurement

BASIC FEATURES:

  • 3-3/4 digits 4000 count
  • Easy to read large LCD
  • Thermo plastic elastomer, high resistance  against drop shock
  • Safety cap on current terminal
  • Data hold, Range hold, Relative function
  • Continuity check, Diode test
  • Auto power off function (30min.)
  • Display : numeral display 4000

SAFETY:

IEC61010-1 (EN61010-1) 2001-02 CAT.III 600V Max.

OPTIONAL ACCESSORIES:

Clamp probe : CL-20D, CL-22AD, CL33DC
HV probe : HV-60
Carrying case : C-77, C-77H
Clip adapter : CL-11, CL-13, CL-15a, CL-DG3a, TL-8IC
Test lead : TL-21M, TLF-120

SPECIFICATIONS:

CD770 Measuring range Best accuracy Resolution Input impedance
DCV 400m/4/40/400/600V ±(0.5%+2) 0.1mV 10M~100MΩ
ACV 4/40/400/600V ±(1.2%+7) 0.001V 10M~11MΩ
DCA 400μ/4000μ/40m/400mA ±(1.4%+3) 0.1μA  
ACA 400μ/4000μ/40m/400mA ±(1.8%+5) 0.1μA
Resistance 400/4k/40k/400k/4M/40MΩ ±(1.2%+5) 0.1Ω
Capacitance 50n/500n/5μ/50μ/100μF ±(5%+10) 0.01nF
Frequency 5/50/500/5k/50k/100kHz ±(0.3%+3) 0.001Hz
Continuity Buzzer sounds at between 0Ω and 85Ω(±45Ω). Open voltage:approx.0.4V
Diode test Open voltage:approx.1.5V
Display numeral display 4000
Sampling rate 3 times/sec.
Bandwidth 40~400Hz(Sine wave)
Fuse 0.5A/250V 1.5kA Φ5×20mm
Battery R6Px2
Battery life Approx.400h (manganese battery) at DCV range
Size/Mass H166×W82×D44mm/340g