Large diameter CT & DMM functions

  • Lightweight approx. 290g
  • Large LCD with backlight
  • Easy to use large size data hold button
  • Non-contact voltage detection function
  • Auto V/Ω detection

Large diameter CT & DMM functions

BASIC FEATURES:

  • Lightweight approx. 290g
  • Large LCD with backlight
  • Easy to use large size data hold button
  • Non-contact voltage detection function
  • Auto V/Ω detection

SAFETY:
IEC61010-2-032 (2002) CAT.III600V Max.

OPTIONAL ACCESSORIES:
Clip adapter : CL-11, CL-13, CL-15a, CL-DG3a, TL-8IC
Test lead : TL-21M, TLF-120

SPECIFICATIONS:

Function Measuring range Best accuracy Resolution
ACA 400/1200A ±(1.7%+5) 0.1A
DCV 6/60/600V ±(0.7%+3) 0.001V
ACV 6/60/600V ±(1.7%+5) 0.001V
Auto resistance 6k/60k/600k/6MΩ ±(1.2%+4)
Resistance 600Ω ±(2.2%+8) 0.1Ω
Frequency 9.999/99.99/9.999k/30kHz ±(0.6%+4) 0.001Hz
Capacitance 100n/1000n/10μ/100μ/2000μF ±(3.7%+5) 0.1nF
Continuity Buzzer sounds at between 0Ω and 155Ω (±145Ω) Open voltage: approx. 0.4V
Diode test Open voltage: approx. 1.6V
Voltage detection Buzzer sounds and “-” is shown on LCD.
Input sensitivity: approx. 20V or over (50/60Hz)
Sampling rate 5 times/sec.
Bandwidth ACA 50/60Hz ACV 50-500Hz
Display 6000
Clamp diameter/Conductor size Φ42mm/20×54mm
Battery R03×2
Battery life Approx. 90 hrs. at DCV (Alkaline battery/Backlight off)
Size/Mass H238×W95×D45mm/Approx. 290g
Safety standards IEC61010 CAT.Ⅲ 600V