PC20 DIGITAL MULTIMETER – SANWA
$0.00
Data processing (PC Link)
AC adapter connectable for long haul measurement
- 4000 counts
- 0.5% best accuracy
- Safety cover for 4・10A terminal
- Safety cap for AC adapter terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
PC20
Digital Multimeters Data processing (PC Link)
AC adapter connectable for long haul measurement
BASIC FEATURES:
- 3-3 / 4 digits 4000 count
- 0.5% best accuracy
- Capacitance mea
- surement
- ※Not suitable for measurement of condensers with large leak current.
- Data hold / Range hold
- Safety cover for the 4・10A terminal
- Safety cap for AC adapter terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
- Optical link RS232C / USB interface (optional)
- Display : numeral display 4000 Sampling rate : 3 times / sec.
- AC frequency bandwidth : 40〜500Hz
- With AC adapter : IEC61010-1 (EN61010-1) 2001-02 CAT.III 200V Max.
OPTIONAL ACCESSORIES:
Software : PC Link 7 Optical PC link cable : KB-USB20
Clamp probe : CL-20D, CL-22AD, CL33DC
Temperature probe : T-300PC (PC Link software is necessary.)
AC adapter : AD-71AC (100V), AD-72AC (220V)
Test lead : TL-21M, TLF-120
Carrying case : C-PC10/S or C-SP
Clip adapter : CL-11, CL-13, CL-15a, CL-DG3a, TL-8IC
SPECIFICATIONS:
PC20 | Measuring range | Best accuracy | Resolution | Input impedancew |
---|---|---|---|---|
DCV | 400m/4/40/400/1000V | ±(0.5%+2) | 0.1mV | 10M~100MΩ |
ACV | 4/40/400/750V | ±(1.2%+5) | 0.001V | 10~11MΩ |
DCA | 400μ/4000μ/40m/400m/4A/10A | ±(1.5%+2) | 0.1μA | |
ACA | 400μ/4000μ/40m/400m/4A/10A | ±(1.8%+5) | 0.1μA | |
Resistance | 400/4k/40k/400k/4M/40M | ±(1.2%+4) | 0.1Ω | |
Capacitance | 50n/500n/5μ/50μ/100μF | ±(5%+6) | 0.01nF | |
Continuity | Buzzer sounds at between 10Ω and 120Ω. Open voltage:Approx.0.4V | |||
Diode test | Open voltage:approx.1.5V |
Display | numeral display 4000 |
Sampling rate | 3 times/sec. |
Bandwidth | 40Hz~500Hz(below 500V) 40Hz~1kHz(ACA) |
Fuse | 0.5A/250V IR1500A Φ5×20mm 12.5A/250V IR125A Φ6.3×32mm |
Battery | R6x2 |
Battery life | Approx.150h (manganese battery) at DCV range |
Size/Mass | H167×W90×D48mm/330g(including holster) |
Related products
-
RD700 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteMultifunction
High input impedance 1000MΩ
- 4000 counts
- Best accuracy0.3%
- K type thermocouple temperature measurement -20℃ – 300℃
- Frequency measurement
※Input voltage:20VACrms and uder
※Input signal:sign wave or square wave with 40% – 70%duty
※Input sensivity:10Hz-20kHz/0.9Vrms and above
:20kHz-500kHz/2.6Vp or 1.9Vrms and above
:500kHz~1MHz/4.2Vp or 3Vrms and above - Max value hold
- Auto power off (30min,)(cancelable)
- Alarm for importer test lead insertion to current terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
-
PC LINK 7 SOFTWARE – SANWA
$0.00Add To QuoteFor easier operation, higher visibility, and… Furbished GUI.
Enhanced new features such as separated graphs, user restrictions, and etc.
Max 8 channels to the PC connection at the same time.- Automatically detects a port connected with a digital multimeter.
- No additional driver installation required with Windows standard USB drivers.
- The retrieval interval can be set by seconds. The shortest reading interval of 0.2 – 0.3 seconds depending on the digital multimeter measuring function.
- Allows setting for vertical/horizontal zoom, reading at the cursor position, and Y axis split while retrieving data.
- Allows automatic retrieval by schedule setting.
- Allows data saving into CSV files and sending e-mails of alert information with alarm setting.
- Allows data saving into CSV files with the date and time appended.
- Multi-window, separated graphs by each channel
- Allows automatic e-mail of measurement data.
- Allows limited operations depending on the user with usage restriction function.
- Allows conditional recording by event function.
-
PC773 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteData processing (PC connectable)
11000 counts, Minimum resolusion 0.01mV,0.01Ω
- 11000 counts
- Best accuracy 0.28%
- Double molding of elastic elastomer materials
- AC/DC current measurable max.11A
- Continuity buzzer and LED lamp
- Auto power save(30min.)(cancelable)
-
PS 8a Digital Multimeter / Pocket type (Solar Charge battery DMM)
$0.00Add To QuoteSolar charge battery DMM / Digital Multimeter
- 4000 counts
- Best accuracy 0.7%
- Auto power off(15min.)
- Low power ohm(input voltage 0.4V)at continuity range
-
PC7000 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteHigh accuracy & high resolution (PC Link)
500000 counts for DCV, Dual display
- 50000 & 500000 counts
(Selectable 5-4 / 5 digits 500000 counts for DCV) - Dual display shows voltage/current and its frequency, and AC components and DC components of voltage/current
- Low-pass filter for variable frequency drive(VFD) circuit
- Capture (peak hold), Interval: 0.8ms
- MAX/MIN/AVG recording mode
- K type thermocouple temperature measurement -50℃ ~ 1000℃
- Conductance measurement
- Auto power save (17min.)(cancelable)
- 50000 & 500000 counts