PC500
Digital Multimeters High accuracy (PC Link)
5000 Count Bar Graph
BASIC FEATURES:
- Fast Response (5 times / sec. in digit and 60times / sec. in bargraph)
- Selectable 5 sensitivity for Frequency measurement
- Capacitance measurement 0.01nF up to 9999uF
- K-type temperature measurement –50oC ~ 1000oC
- Auto Lead Resistance Calibration
- 0.08% Basic Accuracy at DCV function
- High resolution: 0.01 ohm, Voltage 0.01mV
- RS-232C Interface
- Data hold
- Auto power off (Enable or Disable)
- Fast response Cont. Buzzer
- Tilt stand
- Set off Beeper function
SAFETY:
 IEC 1010-1 CAT III Max.600V, CAT II Max. 1000V EN50081-1, EN50082-1
SPECIFICATIONS:
Range |
Accuracy |
||
Function-DCV | |||
50.00mV | ±(0.12%rdg+2dgt) | ||
500.0mV | ±(0.06%rdg+2dgt) | ||
5.000V | ±(0.08%rdg+2dgt) | ||
50.00V | |||
500.0V | |||
1000V | |||
Function-ACV | |||
Bandwidth |
50~60Hz
|
40~500Hz
|
up to 20kHz
|
50.00mV | ±(0.5%rdg+5dgt) | ±(0.8%rdg+3dgt) | 0.5dB |
500.0mV | |||
5.000V | ±(1%rdg+4dgt) | 3dB | |
50.00V | |||
500.0V | |||
1000V | ±(1.0%rdg+40dgt) | Unspec’d | |
Function-W | |||
50.00W | ±(0.4%rdg+6dgt) | ||
500.0W | ±(0.2%rdg+3dgt) | ||
5.000kW | ±(0.2%rdg+2dgt) | ||
50.00kW | |||
500.0kW | |||
5.000MW | ±(1.0%rdg+3dgt) | ||
50.00MW | ±(1.5%rdg+5dgt) | ||
Open Voltage: <1.3VDC, <3VDC for 50W&500W range | |||
Function-Capacity | |||
50.00nF | ±(0.8%rdg+3dgt) | ||
500.0nF | |||
5.000µF | ±(1.0%rdg+3dgt) | ||
50.00µF | ±(2.0%rdg+3dgt) | ||
500.0µF | ±(3.5%rdg+5dgt) | ||
9999µF | ±(5.0%rdg+5dgt) | ||
Function-DCA | |||
500.0µA | ±(0.2%rdg+4dgt) | ||
5000µA | |||
50.00mA | |||
500.0mA | |||
5.000A | |||
10.00A | |||
Function-ACA | |||
Bandwidth |
50~60Hz
|
40~1kHz
|
500.0µA | ±(0.6%rdg+3dgt) | ±(0.8%rdg+4dgt) |
5000µA | ||
50.00mA | ||
500.0mA | ±(1%rdg+3dgt) | ±(1.0%rdg+4dgt) |
5.000A | ±(0.6%rdg+3dgt) | |
10.00A | ||
Frequency | ||
5.000Hz~125kHz | ±(0.01%rdg+2dgt) | |
Temperture(PC520M/PC510) | ||
-50ºC~1000ºC | ±(0.3%rdg+3dgt) | |
Continity buzzer | ||
Buzzer sounds at between 20W~120W Open voltage: Approx. 3V | ||
Diode test | ||
Open voltage: Approx. 3.5V |
rdg : reading / dgt : digits
OPTIONAL ACCESSORIES:
Clamp Probe (CL33DC) | |
Clamp Probe (CL-22AD) | |
Clamp Probe (CL-20D) | |
*Temperature Probe (T-300PC) | |
Carrying Case (C-CD) | |
RS-232C cable (KB-RS2) | |
Software (PC Link / PC Link Plus) | |
* | Temperature Probe , which is Platinic thin film (-50 to 300oC), can be used with only PC Link or PC Link Plus through RS-232C cable (KB-RS2). |
Category: Digital Multimeters
Related products
-
PC LINK 7 SOFTWARE – SANWA
Add To QuoteFor easier operation, higher visibility, and… Furbished GUI.
Enhanced new features such as separated graphs, user restrictions, and etc.
Max 8 channels to the PC connection at the same time.- Automatically detects a port connected with a digital multimeter.
- No additional driver installation required with Windows standard USB drivers.
- The retrieval interval can be set by seconds. The shortest reading interval of 0.2 – 0.3 seconds depending on the digital multimeter measuring function.
- Allows setting for vertical/horizontal zoom, reading at the cursor position, and Y axis split while retrieving data.
- Allows automatic retrieval by schedule setting.
- Allows data saving into CSV files and sending e-mails of alert information with alarm setting.
- Allows data saving into CSV files with the date and time appended.
- Multi-window, separated graphs by each channel
- Allows automatic e-mail of measurement data.
- Allows limited operations depending on the user with usage restriction function.
- Allows conditional recording by event function.
-
RD700 DIGITAL MULTIMETER – SANWA
Add To QuoteMultifunction
High input impedance 1000MΩ
- 4000 counts
- Best accuracy0.3%
- K type thermocouple temperature measurement -20℃ – 300℃
- Frequency measurement
※Input voltage:20VACrms and uder
※Input signal:sign wave or square wave with 40% – 70%duty
※Input sensivity:10Hz-20kHz/0.9Vrms and above
:20kHz-500kHz/2.6Vp or 1.9Vrms and above
:500kHz~1MHz/4.2Vp or 3Vrms and above - Max value hold
- Auto power off (30min,)(cancelable)
- Alarm for importer test lead insertion to current terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
-
RD701 DIGITAL MULTIMETER – SANWA
Add To QuoteHigh input impedance 1000MΩ
- 4000 counts
- Best accuracy 0.3%
- K type thermocouple temperature measurement -20℃ – 300℃
- Frequency measurement
※Input voltage:20VACrms and under
※Input signal:sing wave or square wave with 40%-70% duty
※Input sensitivity:10Hz~20kHz/0.9Vrms and above
:20kHz~500kHz/2.6Vp or 1.9Vrms and above
:500kHz~1MHz/4.2Vp or 3Vrms and above - Max value hold
- Auto power off (30min.)(cancelable)
- Alarm for importer test lead insertion to current terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
-
PC20 DIGITAL MULTIMETER – SANWA
Add To QuoteData processing (PC Link)
AC adapter connectable for long haul measurement
- 4000 counts
- 0.5% best accuracy
- Safety cover for 4・10A terminal
- Safety cap for AC adapter terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
-
PC700 DIGITAL MULTIMETER – SANWA
Add To QuoteHigh accuracy (PC Link)
Dual display, Best accuracy 0.06%
- 6000&9999 counts
- DC/AC voltage measurement resolution 0.01mV
- Dual display shows voltage/current and its frequency, and AD components and DC components of voltage/current
- High speed bar graph
- Auto power save (30min.)(cancelable)
Contact Us
For Quotes:
email: info@bhumika.ca
phone: 613-619-0894