PC5000 DIGITAL MULTIMETER – SANWA
NOTE: This item has been discontinued by SANWA. We have a few units that’s available in stock, and are available at great prices.
PC 5000
Digital Multimeters High accuracy (PC Link)
AC / AC+DC True RMS 50000 & 500000 count (DCV & Hz function) selectable
BASIC FEATURES:
- AC / AC+DC True RMS
- 50000 & 500000 count (DCV & Hz function) selectable
- Fast Response (5 times / sec. in digit and 60times / sec. in bargraph)
- Selectable 5 sensitivity for Line Frequency measurement
- Capacitance measurement 0.01nF up to 9.999mF
- 0.03% Basic Accuracy at DCV function
- High resolution: 0.01 ohm, Voltage 0.01mV
- dBm measurement 20 selectable reference impedance
- %4-20mA measurement
- Duty Cycle measurement
- Logic Frequency measurement
- RS-232C Interface
- MAX, MIN Recording mode
- MAX. MIN Capture mode (peak hold) 0.8ms in duration
- Data hold
- Auto power off (Enable or Disable)
- Fast response Cont. Buzzer
- Alarm for wrong plug insertion in uA mA & A terminal
- Tilt stand
- Set off Beeper function
SAFETY:
IEC 1010-1 CAT III Max.600V, CAT II Max. 1000VÂ EN50081-1, EN50082-1
SPECIFICATIONS:
Range |
Accuracy |
||
Function-DCV | |||
500.00mV | ±(0.03%rdg+2dgt) | ||
5.0000V | |||
50.000V | |||
500.00V | ±(0.05%rdg+2dgt) | ||
1000.0V | ±(0.1%rdg+2dgt) | ||
Function-AC/AC+DC V | |||
Bandwidth |
45~300Hz
|
300~1kHz
|
1kHz~5kHz
|
500.00mV | ±(0.8%rdg+60dgt) | ±(0.8%rdg+40dgt) |
1dB
|
5.0000V | ±(0.2%rdg+60dgt) | 2dB | |
50.000V | |||
500.00V | 3dB | ||
1000.0V | ±(1.0%rdg+40dgt) | Unspec’d | |
Function-W | |||
500.00W | ±(0.2%rdg+6dgt) | ||
5.0000kW | |||
50.000kW | |||
500.00kW | |||
5.0000MW | ±(0.8%rdg+6dgt) | ||
50.000MW | ±(2%rdg+6dgt) | ||
Open Voltage: <1.3VDC, <3VDC for 500W range | |||
Function-Capacity | |||
50.00nF | ±(0.8%rdg+3dgt) | ||
500.0nF | |||
5.000µF | ±(1.0%rdg+3dgt) | ||
50.00µF | ±(2.0%rdg+3dgt) | ||
500.0µF | ±(3.5%rdg+5dgt) | ||
9999µF | ±(5.0%rdg+5dgt) | ||
Function-DCA | |||
500.00µA | ±(0.15%rdg+20dgt) | ||
5000.0µA | ±(0.1%rdg+2dgt) | ||
50.000mA | ±(0.15%rdg+10dgt) | ||
500.00mA | ±(0.1%rdg+2dgt) | ||
5.0000A | ±(0.5%rdg+10dgt) | ||
10.000A | ±(0.5%rdg+2dgt) | ||
Function-AC(AC+DC)A | |||
Bandwidth |
50~60Hz
|
40~1kHz
|
500.00µA | ±(1%rdg+4dgt) | ±(1.0%rdg+40dgt) |
5000.0µA | ||
50.000mA | ||
500.00mA | ||
5.0000A | ||
10.000A | ||
Frequency | ||
5.0000Hz~200.000kHz | ±(0.002%rdg+4dgt) | |
Logic Frequency | ||
5.0000Hz~2.00000MHz | ±(0.002%rdg+4dgt) | |
Duty Cycle | ||
0.1%~99.99% | ±(3d/kHz+2dgt) | |
dBm | ||
-11.76dBm~54.25dBm at 600W±(0.25dB + 2dgt) | ||
%4~20m | ||
4mA (0%) – 20mA (100%) | +/- 25d | |
Continity buzzer | ||
Buzzer sounds at between 20W~120W Open voltage: Approx. 3V | ||
Diode test | ||
Open voltage: Approx. 3.5V |
rdg : reading / dgt : digits
Related products
-
PC720M DIGITAL MULTIMETER SANWA
Add To QuoteHigh accuracy & built-in memory (PC Link)
87,382 points data logging in built-in memory
- 6000&9999 counts
- Dual display with blacklight
- High speed bar graph
- K type thermocouple temperature measurement -50℃ ~ 1000℃
- Conductance measurement
- MAX/MIN recoding mode
- Caputure (peak hold), Interval: 1ms
- Auto power save (30min.)(cancelable)
-
PM10 DIGITAL MULTIMETER – SANWA
Add To QuoteNOTE: This item has been discontinued by SANWA. We have a few units that’s available in stock, and are available at great prices.
-
PC LINK 7 SOFTWARE – SANWA
Add To QuoteFor easier operation, higher visibility, and… Furbished GUI.
Enhanced new features such as separated graphs, user restrictions, and etc.
Max 8 channels to the PC connection at the same time.- Automatically detects a port connected with a digital multimeter.
- No additional driver installation required with Windows standard USB drivers.
- The retrieval interval can be set by seconds. The shortest reading interval of 0.2 – 0.3 seconds depending on the digital multimeter measuring function.
- Allows setting for vertical/horizontal zoom, reading at the cursor position, and Y axis split while retrieving data.
- Allows automatic retrieval by schedule setting.
- Allows data saving into CSV files and sending e-mails of alert information with alarm setting.
- Allows data saving into CSV files with the date and time appended.
- Multi-window, separated graphs by each channel
- Allows automatic e-mail of measurement data.
- Allows limited operations depending on the user with usage restriction function.
- Allows conditional recording by event function.
-
PC710 DIGITAL MULTIMETER – SANWA
Add To QuotePeak hold function, temperature probe included
True RMS, Dual display
- 6000&9999 counts
- Dual display shows voltage/current and its frequency, and AC components and DC components of voltage/current
- EF(Electric Field)detection to indicate signal strength of electric field which surrounds current carrying conductors
- Capture (peak hold), Interval:1ms
- MAX/MIN/AVG recording mode
- K type thermocouple temperature measurement -50℃ ~ 1000℃
- Conductance measurement
- Auto power save (17min.) (cancelable)
-
RD700 DIGITAL MULTIMETER – SANWA
Add To QuoteMultifunction
High input impedance 1000MΩ
- 4000 counts
- Best accuracy0.3%
- K type thermocouple temperature measurement -20℃ – 300℃
- Frequency measurement
※Input voltage:20VACrms and uder
※Input signal:sign wave or square wave with 40% – 70%duty
※Input sensivity:10Hz-20kHz/0.9Vrms and above
:20kHz-500kHz/2.6Vp or 1.9Vrms and above
:500kHz~1MHz/4.2Vp or 3Vrms and above - Max value hold
- Auto power off (30min,)(cancelable)
- Alarm for importer test lead insertion to current terminal
- Protective holster with wall hanger and lead holder
- Tilt stand