PC7000 DIGITAL MULTIMETER – SANWA
$0.00
High accuracy & high resolution (PC Link)
500000 counts for DCV, Dual display
- 50000 & 500000 counts
(Selectable 5-4 / 5 digits 500000 counts for DCV) - Dual display shows voltage/current and its frequency, and AC components and DC components of voltage/current
- Low-pass filter for variable frequency drive(VFD) circuit
- Capture (peak hold), Interval: 0.8ms
- MAX/MIN/AVG recording mode
- K type thermocouple temperature measurement -50℃ ~ 1000℃
- Conductance measurement
- Auto power save (17min.)(cancelable)
PC 7000
Digital Multimeters – High accuracy (PC Link)
500000 Count for DCV, Dual Display
BASIC FEATURES:
- 4-4 / 5digits 50000 count
(Selectable 5-4 / 5 digits 500000 count for DCV) - Dual Display shows voltage/current and its frequency, and AC components and DC
components of voltage/current - AC True RMS
- Low-pass filter for variable frequency drive(VFD)  circuit
- Current (mA / μA) %4-20mA measurement
- Capture (peak hold) 0.8ms in duration
- MAX, MIN, AVE recording mode
- K type temperature -50℃〜1000℃
※Optional accessory K-AD is necessary.
※K type temp. sensor K-250PC is included as a standard accessory.
â– Frequency measurement (AC sine wave only)
â– Logic frequency measurement, duty cycle
measurement
â– Conductance measurement
â– Dual display with backlight
â– Data hold, Range hold
â– Relative value
â– Auto power saving mode (30min.) (cancelable)
â– Optical Link USB interface (optional)
Display : numeral display 50000 & 500000 selectable, bar graph 41 segments
Sampling rate : 5 times/sec. for 50000 count, 1.25 times/sec. for 500000 count, 60 times/sec. for bar graph
Battery life : Approx. 100h (alkaline battery) at DCV range
â– Optical Link USB interface (optional)
Display : numeral display 50000 & 500000 selectable, bar graph 41 segments
Sampling rate : 5 times/sec. for 50000 count, 1.25 times/sec. for 500000 count, 60 times/sec. for bar graph
Battery life : Approx. 100h (alkaline battery) at DCV range
SAFETY:
IEC61010-1:2001, IEC61010-31:2008 CAT.III 600V
Max./CAT. II 1000V Max., EN61326-1:2006
Max./CAT. II 1000V Max., EN61326-1:2006
OPTIONAL ACCESSORIES:
Software : PC Link7
Optical PC link cable : KB-USB7
Clamp probe : CL124, CL140, CL-20D, CL-22AD, CL33DC
Temperature probe : T-300PC (PC Link software is necessary.) K-8-250〜800
K type adapter : K-AD
Test lead : TL-21M, TLF-120
Carrying case : C-PC7
Clip adapter : CL-11, CL-13, CL-15a, CL-DG3a, TL-8IC
Optical PC link cable : KB-USB7
Clamp probe : CL124, CL140, CL-20D, CL-22AD, CL33DC
Temperature probe : T-300PC (PC Link software is necessary.) K-8-250〜800
K type adapter : K-AD
Test lead : TL-21M, TLF-120
Carrying case : C-PC7
Clip adapter : CL-11, CL-13, CL-15a, CL-DG3a, TL-8IC
SPECIFICATIONS:
PC7000 | Measuring range | Best accuracy | Resolution | Input impedance |
---|---|---|---|---|
DCV | 500m/5/50/500/1000V | ±(0.03%+2) | 0.01mV | 10MΩ |
ACA | 500m/5/50/500/1000V | ±(0.5%+40) | 0.01mV | |
DCA | 500μ/5000μ/50m/500m/5/10A | ±(0.1%+20) | 0.01μA | |
ACA | 500μ/5000μ/50m/500m/5/10A | ±(0.6%+40) | 0.01μA | |
Resistance | 500/5k/50k/500k/5M/50MΩ | ±(0.2%+6) | 0.01Ω | |
Conductance | 99.99nS | ±(1.0%+10) | 0.01nS | |
Capacitance | 50n/500n/5μ/50μ/500μ/5m/25mF | ±(0.8%+3)※ | 0.01nF | |
Temperature | -50~1000°C(thermocouple K type) | ±(0.3%+20) | 0.1°C | |
Frequency | 10Hz~200kHz | ±(0.02%+40) | 0.001Hz | |
Logic frequency | 5Hz~2MHz | ±(0.002%+4) | 0.001Hz | |
Duty cycle | 0.1%~99.99% | ±(3d/kHz+2) | 0.01% | |
dBm | -29.83dBm~54.25dBm | ±(0.25dB+2) | 0.01dB | |
4-20mA% | 4mA=0% 20mA=100% |
±25d | 0.01% | |
Continuity | Buzzer sounds at between 20Ω and 200Ω Open voltage:approx.1.3 | |||
Diode test | Open voltage:approx.3V |
Display | numeral display 50000 & 500000 selectable, bar graph 41 segments |
Sampling rate | 5 times/sec. for 50000 count, 1.25 times/sec.for 500000 count, 60 times/sec.for bar graph |
Bandwidth | V:45Hz~1kHz,1kHz~20kHz(below 500V) A:40Hz~1kHz |
Fuse | 11A/1000V IR20kA Φ10× 38 mm 0.4A/1000V IR30kA Φ 6.3× 32 mm |
Battery | 6LR61(9V)x1 |
Battery life | Approx.100h (alkaline battery) at DCV range |
Size/Mass | H184×W86×D52mm/approx.430g(Including Holster) |
Safety | IEC61010 CAT.Ⅲ600V/CAT.Ⅱ1000V |
※Accuracies with film capacitor or better, which has low leakage current
Category: Digital Multimeters
Related products
-
KP1 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteVolt Tester
CAT.IV Volt tester
- Self test-checking failures of LCD, disconnection of a lead wire
- EF(Electric Field)detection
- LCD with backlight & LED Light for dark place
- Auto data hold
- Auto power off(1min.)
- Auto identification of AC or DC voltage
-
RD700 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteMultifunction
High input impedance 1000MΩ
- 4000 counts
- Best accuracy0.3%
- K type thermocouple temperature measurement -20℃ – 300℃
- Frequency measurement
※Input voltage:20VACrms and uder
※Input signal:sign wave or square wave with 40% – 70%duty
※Input sensivity:10Hz-20kHz/0.9Vrms and above
:20kHz-500kHz/2.6Vp or 1.9Vrms and above
:500kHz~1MHz/4.2Vp or 3Vrms and above - Max value hold
- Auto power off (30min,)(cancelable)
- Alarm for importer test lead insertion to current terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
-
CD771 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteMultifunctional new standard
Backlight & Cont.buzzer with LED
- 4000 counts
- Easy to read large LCD with backlight
- Large breaking capacity fuse 30kA
- 1.5V battery check function
- Thermo plastic elstomer, high resistance against drop shock
- Safety cap on current terminal
- Auto power off(30min.)(cancelable)
-
PC LINK 7 SOFTWARE – SANWA
$0.00Add To QuoteFor easier operation, higher visibility, and… Furbished GUI.
Enhanced new features such as separated graphs, user restrictions, and etc.
Max 8 channels to the PC connection at the same time.- Automatically detects a port connected with a digital multimeter.
- No additional driver installation required with Windows standard USB drivers.
- The retrieval interval can be set by seconds. The shortest reading interval of 0.2 – 0.3 seconds depending on the digital multimeter measuring function.
- Allows setting for vertical/horizontal zoom, reading at the cursor position, and Y axis split while retrieving data.
- Allows automatic retrieval by schedule setting.
- Allows data saving into CSV files and sending e-mails of alert information with alarm setting.
- Allows data saving into CSV files with the date and time appended.
- Multi-window, separated graphs by each channel
- Allows automatic e-mail of measurement data.
- Allows limited operations depending on the user with usage restriction function.
- Allows conditional recording by event function.
-
PC20 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteData processing (PC Link)
AC adapter connectable for long haul measurement
- 4000 counts
- 0.5% best accuracy
- Safety cover for 4・10A terminal
- Safety cap for AC adapter terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
Contact Us