Category
Most Popular Products
Product was successfully added to quote request.View List
PC7000 DIGITAL MULTIMETER – SANWA
$0.00
High accuracy & high resolution (PC Link)
500000 counts for DCV, Dual display
- 50000 & 500000 counts
(Selectable 5-4 / 5 digits 500000 counts for DCV) - Dual display shows voltage/current and its frequency, and AC components and DC components of voltage/current
- Low-pass filter for variable frequency drive(VFD) circuit
- Capture (peak hold), Interval: 0.8ms
- MAX/MIN/AVG recording mode
- K type thermocouple temperature measurement -50℃ ~ 1000℃
- Conductance measurement
- Auto power save (17min.)(cancelable)
PC 7000
Digital Multimeters – High accuracy (PC Link)
500000 Count for DCV, Dual Display
BASIC FEATURES:
- 4-4 / 5digits 50000 count
(Selectable 5-4 / 5 digits 500000 count for DCV) - Dual Display shows voltage/current and its frequency, and AC components and DC
components of voltage/current - AC True RMS
- Low-pass filter for variable frequency drive(VFD)  circuit
- Current (mA / μA) %4-20mA measurement
- Capture (peak hold) 0.8ms in duration
- MAX, MIN, AVE recording mode
- K type temperature -50℃〜1000℃
※Optional accessory K-AD is necessary.
※K type temp. sensor K-250PC is included as a standard accessory.
â– Frequency measurement (AC sine wave only)
â– Logic frequency measurement, duty cycle
measurement
â– Conductance measurement
â– Dual display with backlight
â– Data hold, Range hold
â– Relative value
â– Auto power saving mode (30min.) (cancelable)
â– Optical Link USB interface (optional)
Display : numeral display 50000 & 500000 selectable, bar graph 41 segments
Sampling rate : 5 times/sec. for 50000 count, 1.25 times/sec. for 500000 count, 60 times/sec. for bar graph
Battery life : Approx. 100h (alkaline battery) at DCV range
â– Optical Link USB interface (optional)
Display : numeral display 50000 & 500000 selectable, bar graph 41 segments
Sampling rate : 5 times/sec. for 50000 count, 1.25 times/sec. for 500000 count, 60 times/sec. for bar graph
Battery life : Approx. 100h (alkaline battery) at DCV range
SAFETY:
IEC61010-1:2001, IEC61010-31:2008 CAT.III 600V
Max./CAT. II 1000V Max., EN61326-1:2006
Max./CAT. II 1000V Max., EN61326-1:2006
OPTIONAL ACCESSORIES:
Software : PC Link7
Optical PC link cable : KB-USB7
Clamp probe : CL124, CL140, CL-20D, CL-22AD, CL33DC
Temperature probe : T-300PC (PC Link software is necessary.) K-8-250〜800
K type adapter : K-AD
Test lead : TL-21M, TLF-120
Carrying case : C-PC7
Clip adapter : CL-11, CL-13, CL-15a, CL-DG3a, TL-8IC
Optical PC link cable : KB-USB7
Clamp probe : CL124, CL140, CL-20D, CL-22AD, CL33DC
Temperature probe : T-300PC (PC Link software is necessary.) K-8-250〜800
K type adapter : K-AD
Test lead : TL-21M, TLF-120
Carrying case : C-PC7
Clip adapter : CL-11, CL-13, CL-15a, CL-DG3a, TL-8IC
SPECIFICATIONS:
PC7000 | Measuring range | Best accuracy | Resolution | Input impedance |
---|---|---|---|---|
DCV | 500m/5/50/500/1000V | ±(0.03%+2) | 0.01mV | 10MΩ |
ACA | 500m/5/50/500/1000V | ±(0.5%+40) | 0.01mV | |
DCA | 500μ/5000μ/50m/500m/5/10A | ±(0.1%+20) | 0.01μA | |
ACA | 500μ/5000μ/50m/500m/5/10A | ±(0.6%+40) | 0.01μA | |
Resistance | 500/5k/50k/500k/5M/50MΩ | ±(0.2%+6) | 0.01Ω | |
Conductance | 99.99nS | ±(1.0%+10) | 0.01nS | |
Capacitance | 50n/500n/5μ/50μ/500μ/5m/25mF | ±(0.8%+3)※ | 0.01nF | |
Temperature | -50~1000°C(thermocouple K type) | ±(0.3%+20) | 0.1°C | |
Frequency | 10Hz~200kHz | ±(0.02%+40) | 0.001Hz | |
Logic frequency | 5Hz~2MHz | ±(0.002%+4) | 0.001Hz | |
Duty cycle | 0.1%~99.99% | ±(3d/kHz+2) | 0.01% | |
dBm | -29.83dBm~54.25dBm | ±(0.25dB+2) | 0.01dB | |
4-20mA% | 4mA=0% 20mA=100% |
±25d | 0.01% | |
Continuity | Buzzer sounds at between 20Ω and 200Ω Open voltage:approx.1.3 | |||
Diode test | Open voltage:approx.3V |
Display | numeral display 50000 & 500000 selectable, bar graph 41 segments |
Sampling rate | 5 times/sec. for 50000 count, 1.25 times/sec.for 500000 count, 60 times/sec.for bar graph |
Bandwidth | V:45Hz~1kHz,1kHz~20kHz(below 500V) A:40Hz~1kHz |
Fuse | 11A/1000V IR20kA Φ10× 38 mm 0.4A/1000V IR30kA Φ 6.3× 32 mm |
Battery | 6LR61(9V)x1 |
Battery life | Approx.100h (alkaline battery) at DCV range |
Size/Mass | H184×W86×D52mm/approx.430g(Including Holster) |
Safety | IEC61010 CAT.Ⅲ600V/CAT.Ⅱ1000V |
※Accuracies with film capacitor or better, which has low leakage current
Category: Digital Multimeters
Related products
-
RD701 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteHigh input impedance 1000MΩ
- 4000 counts
- Best accuracy 0.3%
- K type thermocouple temperature measurement -20℃ – 300℃
- Frequency measurement
※Input voltage:20VACrms and under
※Input signal:sing wave or square wave with 40%-70% duty
※Input sensitivity:10Hz~20kHz/0.9Vrms and above
:20kHz~500kHz/2.6Vp or 1.9Vrms and above
:500kHz~1MHz/4.2Vp or 3Vrms and above - Max value hold
- Auto power off (30min.)(cancelable)
- Alarm for importer test lead insertion to current terminal
- Protective holster with wall hanger and lead holder
- Tilt stand
-
KP1 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteVolt Tester
CAT.IV Volt tester
- Self test-checking failures of LCD, disconnection of a lead wire
- EF(Electric Field)detection
- LCD with backlight & LED Light for dark place
- Auto data hold
- Auto power off(1min.)
- Auto identification of AC or DC voltage
-
PM3 DIGITAL MULTIMETER – SANWA
$0.00Add To QuotePocket type
8.5mm thick body with multi-function
- 4000 counts
- Best accuracy 0.7%
- Auto power off(15min.)(cancelable)
-
PM10 DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteNOTE: This item has been discontinued by SANWA. We have a few units that’s available in stock, and are available at great prices.
-
CD800a DIGITAL MULTIMETER – SANWA
$0.00Add To QuoteALL-IN-ONE DMM
Tough body cover
- 4000 counts
- Best accuracy 0.7%
- Auto power off(30min.)(cancelable)
- Low power ohm(input voltage 0.4V)at continuity range
- Solid & portective body cover that can also be used as a tilt stand
- Chip resister holder behind the body cover
Contact Us
For Quotes:
email: info@bhumika.ca
phone: 613-619-0894