Based in Canada, we deliver across North America

info@bhumika.ca

Test and Measurement Solutions

PC710 DIGITAL MULTIMETER – SANWA

$0.00

Peak hold function, temperature probe included

True RMS, Dual display

  • 6000&9999 counts
  • Dual display shows voltage/current and its frequency, and AC components and DC components of voltage/current
  • EF(Electric Field)detection to indicate signal strength of electric field which surrounds current carrying conductors
  • Capture (peak hold), Interval:1ms
  • MAX/MIN/AVG recording mode
  • K type thermocouple temperature measurement -50℃ ~ 1000℃
  • Conductance measurement
  • Auto power save (17min.) (cancelable)

PC710

Digital Multimeters – High accuracy (PC Link)

True RMS, Dual Display

 

BASIC FEATURES:

  • 4 digits 9999 count & 3-5/6 digits 6000 count
  • Dual Display shows voltage/current and its frequency, and AC components and DC components of voltage/current
  • AC True RMS
  • EF(Electric Field) Detection to indicate signal strength of electric field which surrounds
    current-carrying conductors
  • Capture (peak hold) 1ms in duration
  • MAX, MIN, AVE recording mode
  • K type temperature -50℃〜1000℃
    ※Optional accessory K-AD is necessary.
    ※K type temp. sensor K-250PC is included as a standard accessory.
  • Frequency measurement (AC sine wave only)
  • Logic frequency measurement, duty cycle measurement
  • Conductance measurement
  • Dual display with backlight
  • Data hold, Range hold
  • Relative value
  • Auto power saving mode (30min.) (cancelable)
  • Optical Link USB interface (optional)
  • Display : numeral display 9999 & 6000, bar graph 41 segments
  • Sampling rate : 5 times/sec., 60 times/sec. for bar graph
  • Max.EN61326-1:2006
  • Battery life : Approx. 60h (manganese battery) at DCV range

SAFETY:

 
IEC61010-1:2001, IEC61010-31:2008 CAT.III 600V Max./CAT. II 1000V

OPTIONAL ACCESSORIES:

Software : PC Link7
Optical PC link cable : KB-USB7
Clamp probe : CL124, CL140, CL-20D, CL-22AD, CL33DC
Temperature probe : T-300PC (PC Link software is necessary.) K-8-250〜800
K type adapter : K-AD
Test lead : TL-21M, TLF-120
Carrying case : C-PC7
Clip adapter : CL-11, CL-13, CL-15a, CL-DG3a, TL-8IC

SPECIFICATIONS:

PC710 Measuring range Best accuracy Resolusion Input impedance
DCV 60m/600m/9.999/99.99/999.9V ±(0.06%+2) 0.01mV 10MΩ
ACV 60m/600m/9.999/99.99/999.9V ±(0.5%+3) 0.01mV
DCA 600μ/6000μ/60m/600m/6/10A ±(0.2%+4) 0.1μA  
ACA 600μ/6000μ/60m/600m/6/10A ±(0.6%+3) 0.1μA
Resistance 600/6k/60k/600k/6M/60MΩ ±(0.1%+3) 0.1Ω
Conductance 99.99S ±(0.8%+10) 0.01nS
Capacitance 60n/600n/6μ/60μ/600μ/6m/25mF ±(0.8%+3)※ 0.01nF
Temperature -50~1000°C(thermocouple K type) ±(0.3%+2) 1°C
Frequency 15Hz~50kHz ±(0.04%+4) 0.01Hz
Logic frequency 5Hz~1MHz ±(0.03%+4) 0.001Hz
Duty cycle 0%~100% ±(3d/kHz+2)  
Continuity Buzzer sounds at between 20Ω and 300Ω Open voltage:approx.1.2V
Diode test Open voltage : approx.3.5V
Electric field sensing (EF) At the standard sensing voltage of about 20V or more,the bar graph and intermittent sound vary in 5 steps
Display numeral display 9999 & 6000, bar graph 41 segments
Sampling rate 5 times/sec.
60 teims/sec.for bar graph
Bandwidth V:40Hz~3kHz 3kHz~20kHz(below 99.99V)
A:40Hz~1kHz
Fuse 11A/1000V IR20kA Φ10× 38 mm
0.4A/1000V IR30kA Φ 6.3× 32 mm
Battery 6F22(9V)x1
Battery life Approx. 60h (manganese battery) at DCV range
Size/Mass H184×W86×D52mm/Approx.430g(including holster)
Safety IEC61010 CAT.Ⅲ600V/CAT.Ⅱ1000V

※Accuracies with film capacitor or better, which has low leakage current