Category
DCM2000DR
DC/AC current measurable max. 2000A, CAT.IV 1000V
- Dual display shows voltage/current and its frequency
- EF (Electric Field) detection
- VFD (Variable Frequency Drive) frequency measurement
- Low input impedance voltage measurement capable of attenuating the effects of ghost voltages
- Peak hold (Interval: 5 ms)
- Auto power save (30 min./Cancelable)
DC/AC current measurable max. 2000A, CAT.IV 1000V –
Clamp Meters
DC/AC+True RMS
DCM2000DR
- Dual display shows voltage/current and its frequency
- EF (Electric Field) detection
- VFD (Variable Frequency Drive) frequency measurement
- Low input impedance voltage measurement capable of attenuating the effects of ghost voltages
- Peak hold (Interval: 5 ms)
- Auto power save (30 min./Cancelable)
SPECIFICATIONS:
Function | Measuring range | Best accuracy | Resolution |
---|---|---|---|
ACA | 200.0/2000A | ±(2.0%+5) | 0.1A |
DCA | 200.0/2000A | ±(2.0%+5) | 0.1A |
ACV | 6.000/60.00/600.0/1000V | ±(1.2%+5) | 0.001V |
DCV | 6.000/60.00/600.0/1000V | ±(0.5%+5) | 0.001V |
Resistance | 600.0/6.000k/60.00k/600.0k/6.000M/40.00MΩ | ±(0.5%+5) | 0.1Ω |
Frequency | 10~1999Hz | ±(0.1%+4) | 0.01Hz |
Capacitance | 60n/600n/6μ/60μ/600μ/2000μF | ±(2.0%+5) | 0.01nF |
Continuity | Buzzer sounds at below 10-200Ω Open voltage: approx. 0.5V | ||
Diode test | Open voltage: approx. 1.8V | ||
EF sensing | A voltage or electric field of about 60 V or more is detected. The bar graph and intermittent buzzer beeps change in three steps according to the field intensity. (50/60Hz) |
Sampling rate | Approx. 5 times/sec. |
Bandwidth | 50~400Hz |
Display | 6000/1999(Hz) |
Max. overload protection input | DC/AC1100V CT: DC/AC2000A |
Clamp diameter/Conductor size | Φ55mm/20x66mm |
Battery | R6Px2 |
Battery life | A function: Approx. 80 hrs. Functions other than A: Approx. 240 hrs. (Zinc-carbon battery/Backlight off) |
Size/Mass | H264×W97×D43mm/Approx. 640g |
Safety standards | IEC61010 CAT.Ⅳ1000V |
Category: Clamp Meters
Related products
-
DCL11R Clamp Meter – SANWA
Add To QuoteRMS mini clamp meter with backlight
- Compact pocket size
- Auto power off (15 min./Cancelable)
-
DCL 1000 CLAMP METER – SANWA
Add To QuoteLarge diameter CT, AC current measurable max. 1000A
- Lightweight approx. 290g
- Large LCD
- Easy to use large size data hold button
-
DCM-400 CLAMP METER – SANWA
Add To QuoteLow cost & DMM functions
- 4000 counts, 42 segments analog bar graph
- Frequency measurement by clamping and using test lead
- Auto power off (30 min.)
- Low battery power indication
-
DCM-660R CLAMP METER – SANWA
Add To QuoteSuitable for electric work and air conditioning & DMM functions
- Inrush current measurement (within 100ms/above 10A)
- MAX/MIN value hold
- Frequency measurement by clamping and using test lead
-
DG34a DIGITAL MULTIMETER CLAMP METER – SANWA
Add To QuoteMΩ Tester
Hybrid pocket size MΩ tester + clamp meter
- 500V; 400MΩ
- 250V; 400MΩ
- 125V; 400MΩ
- Lightweight approx. 160g
- DCV/ACV measurement functions
- DC/AC current measurable up to 100A
- Test leads holder
- U-shaped clamp sensor, 7mm thick
Contact Us
For Quotes:
email: info@bhumika.ca